Technology 

Two main technical logics are used to give MS-RDK products great efficacy.
The effect of the MS-RDK installation is very effective.

4.jpg

Technology logic (1)

The round holes on MS-RK generate turbulence without reducing the intake air volume, thereby preventing air stagnation behind the indoor unit's fan before heat exchange and smoothly feeding the airflow to the heat exchanger.

(Analytical simulation of airflow conducted by the Nagoya Municipal Industrial Research Institute)

Simulation of Airflow Changes

The simulation shows that the velocity of the intake airflow drops, the stagnations is reduced after MS-RDK is installed 

Simulation of Intake Airflow Changes

The graph shows that installing the MS-RDK does not lower the air intake volume or cause the air conditioning efficiency to drop

7.jpg

Technology logic (2)

MS-RDK, a high infrared radiation material, resonates and excites water molecules found in the air. These activated water molecules are miniaturized to promote phase change (vaporization). In addition, the generated turbulence increase the heat conductivity, and the larger heat flux increase the air conditioning efficiency.

14.5%

energy-reducing effect

Air-conditioning performance test based on JIS Standars

An energy-saving effect of 14.5% was confirmed in an air-conditioning performance test (using a Gas Heat Pump air conditioner (GHP)) based on JIS Standards at a major electric power company.

image_edited.jpg

INTAKE TEMPERATURE AFTER INSTALLATION

Thermography

The thermography images show that after installing MS-RDK, the blue and yellow areas are increasing, and cooling is progressing. (Approx. -2.7℃ drop) 

<During cooling>

img38.jpg
img39.jpg

Before installation

After installation

After MS-RDK was installed, the indoor unit's heat exchange efficiency improved, and the blowout temperature increased from 47.4℃ to 49.2℃.

<During heating>

img40.jpg
img41.jpg

Before installation

After installation

Performance evaluation test at LG Electronics, South Korea (following ISO Standards)

Performance evaluation test at air conditioner manufacturer "LG Electronics" (ISO Standards)

The test showed that when MS-RDK was installed, the temperature difference (intake - blowout) per 1kW of power consumption was 0.47℃ higher, indicating that the efficiency had increased by 13.1%)

The temperature variation per 1kW is 0.47℃ higher when MS-RDK is installed.

Energy efficiency

(Without MS-RDK)

27.0℃ - 13.35℃/4.39kW = 3.11 (℃/kW)

Energy efficiency

(With MS-RDK)

27.0℃ - 11.84℃/4.23kW = 3.58 (℃/kW)

*Performance evaluated at 27℃ room temperature, 35℃ outdoor temperature, 19℃ air conditioner setting temperature

MS- RDK: Sonas Corporation